Skip to main content

RIDER-NEURO-MRI

The Cancer Imaging Archive

RIDER NEURO MRI | RIDER NEURO MRI

DOI: 10.7937/K9/TCIA.2015.VOSN3HN1 | Data Citation Required | Image Collection

Location Species Subjects Data Types Cancer Types Size Status Updated
Brain Human 19 MR Brain Cancer 7.79GB Limited, Complete 2011/11/08

Summary

RIDER Neuro MRI contains imaging data on 19 patients with recurrent glioblastoma who underwent repeat imaging sets.  These images were obtained approximately 2 days apart (with the exception of one patient, RIDER Neuro MRI-1086100996, whose images were obtained one day apart).   

DCE‐MRI:  All 19 patients had repeat dynamic contrast‐enhanced MRI (DCE‐MRI) datasets on the same 1.5T imaging magnet.  On the basis of T2‐weighted images, technologists chose 16 image locations using 5mm thick contiguous slices for the imaging.  For T1 mapping, multi‐flip 3D FLASH images were obtained using flip angles of 5, 10, 15, 20, 25 and 30 degrees, TR of 4.43 ms, TE of 2.1 ms, 2 signal averages.  Dynamic images were obtained during the intravenous injection of 0.1mmol/kg of Magnevist intravenous at 3ccs/second, started 24 seconds after the scan had begun.  The dynamic images were acquired using a 3D FLASH technique, using a flip angle of 25 degrees, TR of 3.8 ms, TE of 1.8 ms using a 1 x1 x 5mm voxel size.  The 16 slice imaging set was obtained every 4.8 sec.

DTI: Seventeen of the 19 patients also obtained repeat diffusion tensor imaging (DTI) sets.  Whole brain DTI were obtained using TR 6000ms, TE 100 ms, 90 degree flip angle, 4 signal averages, matrix 128 x 128,  1.72 x 1.72 x 5 mm voxel size, 12 tensor directions, iPAT 2, b value of 1000 sec/mm2 .

Contrast‐enhanced 3D FLASH: All 19 patients underwent whole brain 3D FLASH imaging in the sagittal plane after the administration of Magnevist.  For this sequence, TR was 8.6 ms, TE 4.1 ms, 20 degree flip angle, 1 signal average, matrix 256 x 256; 1mm isotropic  voxel  size.

Contrast‐enhanced 3D FLAIR: All 17 patients who had repeat DTI sets also had 3D FLAIR sequences in the sagittal plane after the administration of Magnevist.  For this sequence, the TR was 6000 ms, TE 353 ms, and TI 2200ms; 180 degree flip angle, 1 signal average, matrix 256 x 216; 1 mm isotropic voxel size. Note: before transmission to NCIA, all image sets with 1mm isotropic voxel size were “defaced” using MIPAV software or manually.


About the RIDER project

The Reference Image Database to Evaluate Therapy Response (RIDER) is a targeted data collection used to generate an initial consensus on how to harmonize data collection and analysis for quantitative imaging methods applied to measure the response to drug or radiation therapy.  The National Cancer Institute (NCI) has exercised a series of contracts with specific academic sites for collection of repeat "coffee break," longitudinal phantom, and patient data for a range of imaging modalities (currently computed tomography [CT] positron emission tomography [PET] CT, dynamic contrast-enhanced magnetic resonance imaging [DCE MRI], diffusion-weighted [DW] MRI) and organ sites (currently lung, breast, and neuro). The methods for data collection, analysis, and results are described in the new Combined RIDER White Paper Report (Sept 2008):

The long term goal is to provide a resource to permit harmonized methods for data collection and analysis across different commercial imaging platforms to support multi-site clinical trials, using imaging as a biomarker for therapy response. Thus, the database should permit an objective comparison of methods for data collection and analysis as a national and international resource as described in the first RIDER white paper report (2006):

Data Access

Some data in this collection contains images that could potentially be used to reconstruct a human face. To safeguard the privacy of participants, users must sign and submit a TCIA Restricted License Agreement to help@cancerimagingarchive.net before accessing the data.

Version 1: Updated 2011/11/08

Title Data Type Format Access Points Subjects Studies Series Images License
Images MR DICOM
Download requires NBIA Data Retriever
19 108 368 70,220 TCIA Restricted
DICOM Metadata Digest CSV CC BY 3.0
Related Datasets
No related Analysis Results found: Submit your proposal! No related Collections found
Legend: Analysis Results| Collections

Citations & Data Usage Policy

Data Citation Required: Users must abide by the TCIA Data Usage Policy and Restrictions. Attribution must include the following citation, including the Digital Object Identifier:

Data Citation

Barboriak, D. (2015). Data From RIDER NEURO MRI. The Cancer Imaging Archive. https://doi.org/10.7937/K9/TCIA.2015.VOSN3HN1

Detailed Description

Pages 19-22 (Appendix 2) of the RIDER White Paper: Combined contracts report ( Sept 2008) PDF cover this data set in great detail.

Related Publications

Publications by the Dataset Authors

The authors recommended this paper as the best source of additional information about this dataset:

No publications by dataset authors were found.

Research Community Publications

TCIA maintains a list of publications which leverage our data. If you have a publication you’d like to add please contact TCIA’s Helpdesk.

Other Publications Using this Data

TCIA maintains a list of publications which leverage our data. If you have a publication you’d like to add please contact TCIA’s Helpdesk.